Magnetic Particle Inspection Yokes

Magnaflux magnetic particle inspection (MPI) testing yokes are designed to be fast and reliable. Versatile and durable for industrial environments magnetic yokes come in a range of outputs, including AC and DC. 

Find out more about how Magnaflux inspection equipment is designed to find indications and defects like fatigue cracks in ferrous materials through wet or dry method mag particle testing.


 


 

 


 

Please wait while we gather your results.

Read More About Magnetic Particle Inspection Equipment

5 Things to Consider When Choosing a Mag Particle Yoke [Checklist]

5 Things to Consider When Choosing a Mag Particle Yoke [Checklist]

In this article we outline some key factors to consider when selecting the right electromagnetic yoke or contour probe for magnetic particle testing

Read More...

Magnetic Particle Inspection Demo

How to Do Visible Magnetic Particle Inspections [Video]

See an overview of visible, dry-method magnetic particle inspection method according to ASTM E1444.

Read More...

Magnetic Particle Inspection Demo

How to Do Fluorescent Mag Particle Inspections [Video]

Watch a demonstration of the magnetic particle inspection method according to ASTM E1444 with basic steps for NDT using fluorescent magnetic particles.

Read More...

Mobile Power Packs Demo

Adaptable Mobile Power Packs for Magnetic Particle Inspection [Video]

Learn how to use M-Series magnetizing equipment to perform Magnetic Particle Inspections on a variety of large, heavy parts.

Read More...

New Magnaflux Magnetic Particle Wet Bench for High Speed Inspections [Video]

New Magnaflux Magnetic Particle Wet Bench for High Speed Inspections [Video]

Universal WE is a multi-directional wet bench designed to meet the speed requirements of high volume production facilities.

Read More...

Mag Particle Settling Volume Test

Mag Particle Carrier Settling Test Performance [Video]

See how three common magnetic particle testing carriers perform in a standard ASTM E1444 settling volume test.

Read More...

Magnaflux Semi-automated System

Magnetic Particle Equipment for OCTG Couplings [Video]

See how Magnaflux's semi-automated magnetic particle testing system simplifies Oil Country Tubular Good coupling inspection.

Read More...

Differences of Using Multi-Directional and Uni-Directional [Case Study]

Differences of Using Multi-Directional and Uni-Directional [Case Study]

In this experiment, we compare the speed of a multi-directional magnetic particle wet bench to a traditional uni-directional method.

Read More...

Magnaflux Database System for NDT Control

Database System for Mag Particle Wet Benches [Video]

Learn how this process-control and efficiency upgrade for mag particle testing helps NDT pros improve quality with less time.

Read More...

Magnetic Particle Equipment Demo

Multi-directional Mag Particle Inspection Equipment [Video]

Watch the versatile MD-Series multi-directional mag particle inspection equipment in action. Learn how this wet bench can help you save time and money.

Read More...

In this article, we review the Nadcap requirements for proper magnetization

9 Magnetic Particle Technique Requirements to Document for Nadcap [Checklist]

In this article, we review the Nadcap requirements for proper magnetization and the importance of documentation for auditors

Read More...

In this article, we explain what a P-Series portable power packs are capable of

3 Ways Magnaflux Improved Power Pack MPI Application

In this article, we explain what a P-Series portable power packs are capable of, and their next generation.

Read More...

Learn how to achieve a high intensity beam of light with UV LEDs for NDT inspection

NRTL: What Does It Mean and Why Does It Matter?

NRTL stands for Nationally Recognized Testing Laboratory, but what does that mean to you?

Read More...

Why carrier oil is a critical part of the MPI process

Importance of Using the Correct Oil for Magnetic Particle Inspection

In this article, we explain why carrier oil is a critical part of the MPI process and which characteristics to look for when choosing an NDT carrier fluid

Read More...

Proactive Ergonomics for MT Field Inspection

Proactive Ergonomics for MT Field Inspection Can Improve Your Bottom Line [SlideShare]

Learn about the most effective risk-reduction measure to increase safety for field inspectors

Read More...

Use the ROI Calculator to learn how multi-directional magnetic particle equipment can save

Magnetic Wet Bench Saves $75,833 a Year with Improved Speed and Efficiency [Case Study]

Use the Universal WE ROI Calculator to learn how multi-directional magnetic particle equipment can save you time and money

Read More...

Importance of Using Magnaflux Authorized Service Centers

Importance of Using Magnaflux Authorized Service Centers

Explaining the who, what, when, where, why, and how of Authorized Service Centers, and why they are best for NDT maintenance and repairs

Read More...

Magnetic Field Safety Guidelines for Pacemakers

Magnetic Field Safety Guidelines for Pacemakers

This article reviews the limitations of operators with cardiac pacemaker’s exposure to magnetic particle inspection equipment.

Read More...

How to Calibrate Your MPI Equipment in 5 Steps

How to Calibrate Your MPI Equipment in 5 Steps

In this article, we will go over the five key factors to successfully calibrate your Magnetic Particle Equipment in reference to ASTM E1444, ASTM E3024, ISO 9934, or Nadcap AC7114/2

Read More...

A Primer on System Performance Checks for High Volume NDT Inspections

This article explores a few of the approaches most Magnetic Particle Inspectors practice to check their system performance at regular intervals

Read More...

Customized Solutions for Unique Needs

Magnetic Particle Equipment – Customized Solutions for Unique Needs

In this article, we show two examples how Magnaflux can customize magnetic particle equipment

Read More...

The most common incorrect assumptions about magnetic particle inspection

10 Misunderstandings about Magnetic Particle Testing

This article discusses the most common incorrect assumptions about magnetic particle inspection and gives you some solutions to combat these misunderstandings

Read More...

A Primer on Magnetic Particle Inspection

A Primer on Magnetic Particle Inspection [SlideShare]

A 4-minute mag particle primer to help you understand why this simple, quick, and effective method is still widely used today.

Read More...

Technique Management Challenges

How Integrated Techniques Can Ease the Pain of Part Variability

This article explores issues many magnetic particle inspection operators face when testing diverse parts that require specific standards and acceptance criteria in a world that does not accept mistakes

Read More...

Magnetic Particle Inspection Demo

5 Quick Tips for Mag Particle Testing [Infographic]

Some handy tips for beginners who are new to magnetic particle testing or NDT pros who want an easy reference guide.

Read More...

In this article, we target magnetic particle inspection and highlight 5 ways the process can be more

5 Ways to Improve Magnetic Particle Processing Efficiency and Reliability

In this article, we target magnetic particle inspection and highlight 5 ways the process can be more efficient and reliable.

Read More...

How to Do Preventative Maintenance for Magnetic Particle Equipment

Read how regular upkeep on mag particle equipment is critical for non-destructive testing to safe guard inspections & reduce downtime.

Read More...

Multidirectional Magnetization for Magnetic Particle Inspection

Learn about multi-directional magnetization applications and how mag particle inspections can benefit from multi-vector magnetization.

Read More...

You want the best solution for your application. We can help you find it.


At Magnaflux, we offer products and solutions for a variety of industries. 
Learn more about how we can help you.

View our products > 

Learn about the industries we serve > 

Contact an expert > 

Subscribe to Magnaflux News:

Magnaflux

155 Harlem Avenue
Glenview, IL 60025, USA
Telephone: +1 847-657-5300
Fax: +1 847-657-5388
Contact Magnaflux Customer Service

Select Your Country North America Mexico Brazil China Europe Russia India New Zealand, Australia, Japan, Southeast Asia
© 2018 Magnaflux - all rights reserved.
top

We have placed cookies on your computer to give you the best possible experience with our website. These cookies are also used to ensure we show you advertising that is relevant to you. If you continue without changing your settings, you are agreeing to our use of cookies to improve your user experience. You can click the cookie settings link on our website to change your cookie settings at any time.